top of page

SIVACON 8PS TRUNKING SYSTEMS
BD2 system

BD2_0.png
Communication.png

data transmission with powerline technology

Safe operation and reliable fire protection

The BD2 system is particularly suited for applications from 160 A to 1,250 A with increased safety requirements. The tested fire barrier and functional endurance in case of fire ensure a high level of safety – and thus represent an optimum solution for large buildings and industrial applications, as well as for shipbuilding. The compact system not only stands out for its safe operating behaviour, but also for its minimum space requirements. It can also be used for the infeed of the smaller

BD01 system.

Easy and quick installation with access protection

The anti-rotation feature and guided installa- tion increase safety during the installation
of the system. The joint block, which includes a single-bolt terminal, permits simple and quick installation with integrated expansion compensation.

Sealable tap-off points protect against unauthorised access. In addition, numerous components such as 3D junction units permit a flexible adaptation to the building structure in question.

Increased transparency
of operation thanks to communication capability

The communication-capable BD2 busbar trunking system with its load detection, remote monitoring and switching, as well as with its lighting control, increases system availability, ensuring greater transparency in your operation. Thanks to the powerline technology of the BD2 system, power and data are transmitted cost-efficiently via the current conductors.

BD2_1.jpg

Junction unit for optimum adaptation to building structures

BD2_2.jpg

Individually equipped tap-off units up to 530 A can be plugged on/off while energised

BD2_3.jpg

Tap-off unit with powerline technology

BD2_4.jpg

Technical data

Busbar coating
19
Insulation
18
Mounting Position
17
Standards
IEC 61439-1/-6
16
Housing material
Galvanised and painted sheet steel
15
Conductor material
Aluminium or copper
14
Connection technology
With integrated expansion compensation, single-bolt terminal
13
Data transmission
Powerline, data cable With integrated expansion compensation, single-bolt terminal
12
Tap-off unit
Up to 530 A
11
Tap-off point
Every 0.5 m on one side, offset on both sides every 0.25 m
10
Fire load (per tap-off point)
-
9
Fire load
Max. 2.0 kWh/m
8
Number of conductors
5
7
Rated short-time withstand current Icw (1s)
Up to 34 kA
6
Rated peak withstand current Ipk
Up to 90 kA
5
Rated current InA
160 A to 1,250 A
4
Degree of protection
IP52, IP55
3
Rated operational voltage Ue
690 V AC
2
Rated insulation voltage Ui
690 V AC
1

התועלת שלך

  • בטיחות לאנשים ולצמחים

  • באמצעות אימות תכנון עם בדיקות לפי

  • IEC 61439-2

  • בטיחות אישית ומפעל במקרה של קשתות באמצעות בדיקות לפי IEC/TR 61641

  • גמישות גבוהה הודות לעיצוב מודולרי חדשני

קבצים להורדה

הורד עכשיו

CHECKLIST

IEC 61439

Project Checklist

PARTNERSHIP

SIVACON S8

Technology Partner

SII ORG

License to mark SIVACON S8 with the "Standard Mark"

IEEE ORG

License to mark SIVACON S8 with the "Quality Mark"

Anchor 1
Anchor 1
bottom of page